Turbine flow meter for oil, as the name suggests, it is used to measure various types of oil. The sensor of turbine flow meter is made of polished 304 or 316 material. Turbine flow meter for oil is easy to install, light in weight and easy to maintain. Cooking oil flow meter, hydraulic oil flow meter, colza oil flow meter, vegetable oil flow meter, diesel oil flow meter are mostly recommended for choosing liquid type turbine flowmeter .
Turbine flow meter for oil supports the measurement of oil, oil-water mixture, tap water, refined oil, light oil, cooking oil, hydraulic oil, colza oil etc. Our company’s turbine flow meter for oil is an accurate instrument connected to the pipeline to measure the flow of liquid.
Turbine flow meter for oil can choose a variety of connection methods. Generally speaking, threaded connections are generally used for pipes within DN40. DN50-DN200 pipes all need flange connection. Buyers can choose the measurement accuracy according to their needs. Tri-clamp connecting is the sanitary process connecting for hygienic application.
The turbine flow meter works by using the magnetic flux of the liquid being “cut”. The electromotive force generated by the cutting liquid flow when the impeller rotates will be received by the converter, and the digital signal will be output through the conversion of the converter.
Measuring diameter | DN4-DN200 |
Applicable media range | impurity-free, low viscosity, no strong corrosive liquid |
Accuracy | 1% |
Connection method | flange, thread, clamping |
Medium temperature | -20°C~80°C |
Nominal pressure | 1.6MPa、4.0MPa、6.3MPa、11MPa、15MPa、26MPa、42MPa |
Precision class | 0.2, 0.5, 1.0, 2.5 |
Signal output | Pulse, 4-20Ma, RS485, HART |
Power supply | DC24V Meter head display 3.6V or DC24V+3.6V |
Ambient temperature | -20°C~60°C |
Relative humidity | 5%~90% |
Meter body material | 304, 316L stainless steel |
Protection class | IP65 |
Explosion-proof grade | ExdIICT6Gb |
Impeller material | 2Cr13 impeller |
Pressure resistance grade | Duplex steel impeller |
Diameter | Normal flow range(m³/h) | Extended flow range(m³/h) | Starting flow rate (m³/h) | Maximum pressure loss (KPa) |
DN4 | 0.04-0.25 | 0.04-0.4 | 0.02 | 120 |
DN6 | 0.1-0.6 | 0.06-0.6 | 0.05 | 80 |
DN10 | 0.2-1.2 | 0.15-1.5 | 0.07 | 50 |
DN15 | 0.6-6 | 0.5-5 | 0.35 | 35 |
DN20 | 0.8-8 | 0.45-9 | 0.3 | 35 |
DN25 | 1-10 | 0.5-10 | 0.4 | 35 |
DN32 | 1.5-15 | 0.8-15 | 0.6 | 35 |
DN40 | 2-20 | 1-20 | 0.6 | 35 |
DN50 | 4-40 | 2-40 | 1 | 35 |
DN65 | 7-70 | 5-70 | 4 | 25 |
DN80 | 10-100 | 7-100 | 5 | 25 |
DN100 | 20-200 | 10-200 | 8 | 25 |
DN125 | 25-250 | 13-250 | 10 | 25 |
DN150 | 30-300 | 15-300 | 12 | 25 |
DN200 | 80-800 | 40-800 | 20 | 25 |
All our liquid turbine flow meter 100% tested and calibrated before shipment to ensure the accuracy, you can ask us to send you the factory testing report paper together with the turbine flow meter.
What liquids are turbine flow meters suitable for?
Liquid turbine flowmeters are measuring instruments used to measure the flow volume of liquids. The liquids that can be measured are pure water, tap water, distilled water, cooling water, circulating water, hot water, fire water, air-conditioning water, vegetable oil, edible oil, rapeseed oil, alcohol, liquor, beer, methanol, ethanol, diesel, gasoline, Hydraulic oil, ammonia water, glue with good fluidity, chemical liquid with low viscosity, etc.