Milk electromagnetic flow meter is also called hygienic or food-grade electromagnetic flow meter, it is a kind of special flow meter used in food, pharmaceutical, beverage and other industries for metering, batching, controlling the filling etc.
Milk electromagnetic flow meter is also called hygienic or food-grade electromagnetic flow meter, it is a kind of special flow meter used in food, pharmaceutical, beverage and other industries for metering, batching, and controlling the filling . Milk flow meter body is made of stainless steel (304 or 316L), and the electrode and lining materials conform to sanitary standards. The whole flow meter structure adopts foreign advanced structure optimization design, which greatly improves the accuracy and repeatability of the magnetic flow meter.
The sanitary electromagnetic flow meter has no flow blocking parts and movable parts in the measuring pipeline, which will not cause pressure loss, and will not cause problems such as wear and blockage. The magnetic milk flow meter has a very long life, It is already an ideal measurement and control instrument for the health and hygienic industry.Milk electromagnetic flow meter can be also used for other food fields liquids , such as juice , drinking water , beverage , medicine etc.
Converter | ||
Compact Type | IP65 | |
Remote Type | IP65(IP68 optional) | |
Measurement sensor | ||
Nominal Diameter | DN15-DN1000 | |
Pressure rating (High pressure can be customized) |
DN6 – DN80, PN<4.0MPa | |
DN100 – DN150, PN<1.6MPa | ||
DN200 – DN1000, PN<1.0MPa | ||
DN1200 – DN2000, PN<0.6MPa | ||
Lining Material | Chloroprene rubber (CR), Polytetrafluoroethylene (PTFE/F4), Fluorinated ethylene propylene (FEP/F46), Teflon(PFA) |
|
Electrode Material | 316L Stainless Steel, Hastelloy C, Hastelloy B, Ti, Ta, Pt | |
Ingress Protection | IP68 | IP65 |
Medium Temperature | -25 – 180℃ | -10 – 80℃ |
Lining Temperature Range | Rubber liner:-20 …+60℃
High-temp rubber liner:-20…+90℃ PTFE liner: -20…+120℃ High-temp PTFE liner: -2O…+ 160℃ Polyurethane liner: -2O…+ 80℃ PFA: -20 …+180℃ |
|
Serial communications | RS-485 | |
Output | Current (4-20 mA) , pulse , frequency , state switch | |
Max measuring error | Measurement value ±0.5%(Flow speed > 1m/s); Measurement value ±0.5% ±2mm/s(Flow speed <1m/s) |
|
Repetitiveness | 0.15% | |
Power supply | 100-240VAC,50/60Hz, 22VDC—26VDC | |
Power consumption | Max 15VA | |
Signal cable | Apply only to remote type | |
Shielded cable | Signal section,wire: 0.5mm2 Cu /AWG20 |
Flow Range Table :
Nominal Diameter | Range | Nominal Diameter | Range | Nominal Diameter | Range |
(mm) | (m 3 /h) | (mm) | (m 3 /h) | (mm) | (m 3 /h) |
DN10 | 0.14 ~ 1.40 | DN125 | 22.08~ 441.56 | DN700 | 692.37 ~13847.40 |
DN15 | 0.32 ~ 6.36 | DN150 | 31.79~ 635.85 | DN800 | 904.32~ 18086.40 |
DN20 | 0.57~ 11.30 | DN200 | 56.52 ~ 1130.4 | DN900 | 1144.5~ 22890.60 |
DN25 | 0.88~ 17.66 | DN250 | 88.31 ~ 1766.25 | DN1000 | 1413.0~ 28260.00 |
DN32 | 1.45~ 28.94 | DN300 | 127.17~ 2543.40 | DN1200 | 2034.7~ 40694.40 |
DN40 | 2.26~ 45.22 | DN350 | 173.09~ 3461.85 | DN1400 | 2769.4~ 55389.60 |
DN50 | 3.35~ 70.65 | DN400 | 226.08~ 4521.60 | DN1600 | 3617.2~ 72345.60 |
DN65 | 5.97~ 119.40 | DN450 | 286.31~ 5722.65 | DN1800 | 4578.1~ 91562.40 |
DN80 | 9.04~ 180.86 | DN500 | 353.25~ 7065.00 | ||
DN100 | 14.13 ~ 282.60 | DN600 | 508.68~ 10173.6 |