Flow meter magnetic type is mainly composed of electrodes, main body shell, lining, converter, transducer etc. Sanitary application magnetic flow meter is designed for volume flow of liquids with a temperature range of minus 30 degrees to 120 degrees, such as beer , fruit juice , medicial fluids ,milk etc.
Flow meter magnetic type is mainly composed of electrodes, main body shell, lining, converter, transducer etc.Lithium battery powered flow meter magnetic type supports GPRS telemetry system.Liquid flow in pipes can be monitored by users at any time and from any location. The flow meter magnetic type  is smart and simple to use .
How to install the flow meter magneti type to ensure the good measuring performance ?Â
Flow meter magnetic type is generally installed on the right side of the pump (cannot be installed on the suction side). In the case of open discharge, the flow meter magnetic type is generally installed at the bottom end where the liquid can be stored. Flow meter magnetic type should be set in this location can reduce the number of air bubbles during the measurement process.
What is the influence elements for lifetime of flow meter magnetic type ?
Numerous elements influence the flow meter magnetic type’s effectiveness and usable time. Assumedly, the “flow meter magnetic type” has chemically interacted with the measuring liquid and the measuring tube has dirt attached. The volume measurement may be impacted by large dirt particles that adhere to the tube’s interior. Magnetic flow meter measurements are affected by rust as well. It is conceivable that if the liquid chemically reacts with the lining of the flow meter magnetic type, it will corrode the pipe and cause the pipe to rust.
Connection | Pipe type: flange / special specifications |
Insertion type: simple/ ball valve type | |
Diameter | Pipe type: DN4-DN2000 |
Insertion type: DN200-DN3000 | |
Range | Standard range |
Extended range | |
Special range | |
Accuracy | Pipe type: ±0.5%R/±1.0%R |
Plug-in type: ±2.5%R | |
Communication protocol | No communication output |
MOSBUS protocol | |
Output method | Frequency output |
Equivalent pulse | |
Digital pulse | |
Four-wire 4-20mA | |
Power supply mode | DC24V |
AC220V | |
Lithium battery | |
Housing | 304 stainless steel |
Carbon steel | |
Explosion-proof | Non-explosion-proof |
Exd [ia] iaqIICT5 | |
Lining | Neoprene |
Polyurethane rubber | |
Polytetrafluoroethylene | |
Teflon | |
PFA | |
Electrode | AISI316L |
Hastelloy-B | |
Hastelloy-C | |
Titanium | |
Tantalum | |
Platinum | |
Tungsten Carbide | |
Accessory Options | One-piece |
External keypad integrated | |
Split type | |
Submersible split type |
Flow Range Table of Electromagnetic Flow Meter :
Nominal Diameter | Range | Nominal Diameter | Range | Nominal Diameter | Range |
(mm) | (m 3 /h) | (mm) | (m 3 /h) | (mm) | (m 3 /h) |
DN10 | 0.14 ~ 1.40 | DN125 | 22.08~ 441.56 | DN700 | 692.37 ~13847.40 |
DN15 | 0.32 ~ 6.36 | DN150 | 31.79~ 635.85 | DN800 | 904.32~ 18086.40 |
DN20 | 0.57~ 11.30 | DN200 | 56.52 ~ 1130.4 | DN900 | 1144.5~ 22890.60 |
DN25 | 0.88~ 17.66 | DN250 | 88.31 ~ 1766.25 | DN1000 | 1413.0~ 28260.00 |
DN32 | 1.45~ 28.94 | DN300 | 127.17~ 2543.40 | DN1200 | 2034.7~ 40694.40 |
DN40 | 2.26~ 45.22 | DN350 | 173.09~ 3461.85 | DN1400 | 2769.4~ 55389.60 |
DN50 | 3.35~ 70.65 | DN400 | 226.08~ 4521.60 | DN1600 | 3617.2~ 72345.60 |
DN65 | 5.97~ 119.40 | DN450 | 286.31~ 5722.65 | DN1800 | 4578.1~ 91562.40 |
DN80 | 9.04~ 180.86 | DN500 | 353.25~ 7065.00 | ||
DN100 | 14.13 ~ 282.60 | DN600 | 508.68~ 10173.6 |