Thermocouple Transmitter produced by Wepower Electronic can directly measure the temperature of liquids, vapors, gases and solid surfaces within the range of -200 to 1800°C in various processes.
Characters Of Thermocouple Transmitter 0-10V:
Thermocouple Transmitter produced by Wepower Electronic can directly display the actual measured temperature on site. The display modes include on-site LED and LCD display, and are equipped with backlight, which means that accurate numbers can be clearly read at night and in strong sunlight. Thermocouple transmitter 0-10V can directly measure the temperature of liquids, vapors, gases and solid surfaces within the range of -200 to 1800°C in various processes.
With the help of the HART modem, the Thermocouple Transmitter may remotely manage information, configure, monitor variables, calibrate, and maintain its model, graduation number, and range.
Parameters:
Type of sensor | Measuring range | Minimum measuring range | Connection type |
PT100 | -200~+850℃ | 10K | 3-wire |
Cu50 | -50~+150℃ | 10K | 3-wire |
B | 400~+1820℃ | 500K | 2-wire |
E | -100~+1000℃ | 50K | 2-wire |
J | -100~+1200℃ | 50K | 2-wire |
K | -180~+1372℃ | 50K | 2-wire |
N | -180~+1300℃ | 50K | 2-wire |
R | -50~+1760℃ | 500K | 2-wire |
S | -500~+1760℃ | 500K | 2-wire |
T | -200~+400℃ | 50K | 2-wire |
Resistance transmitter | 0~4500Ω | 10Ω | 2-wire |
Product Name | Thermocouple Transmitter 0-10V |
Explosion-proof grade: | d∥BT4, d∥CT5 |
Input | thermal resistance Pt100, Pt1000 (-200~600℃) |
Thermocouple K, E, S, B, T, J, N | |
Output | 4-20mA signal within the measuring range can be linear with the output resistance signal of the thermal resistance thermometer, can be linear with the input temperature signal of the thermal resistance thermometer. |
4-20Ma can be linear with the millivolt signal input by the thermocouple, It can also be linear with the input temperature signal of the thermocouple thermometer. | |
Process Connecting | 1: No fixed device; 2: Fixing thread; 3: Movable flange; 4: Fixed flange; 5:Rectangular movable flange; 6: Taper thermowell and fixing thread |
Basic error | ±0.2%, ±0.5% |
Power Supply | 12-35VDC |
Transmission method | Two-wire system |
Electrical interface | M20x1.5, NPT1 / 2 |
Measuring range | Thermocouple :0~1300 degrees Celsius(0-1100℃for long time usage) |
RTD : -200~500 ℃ | |
Protecting tube material | 1Cr18Ni9Ti /SS304/SS316/SS316L/SS310S/ |
Thermocouple Wire Dia | 2mm/2.5mm (Can be customized ) |
Dispalying | LED/LCD/ Without display |
Shipping | By air, sea, express |
Sample time | 2~5 days |
Manufacture time | 7~30 days depending on order quantity |
Installation Guidance: